Our products :: Meter order sheet

- Remember that more features means higher price. Don't ask for more functions unless specifically required by your utility.

- All meters are available as IEC or ANSI S-base models.

 

Order sheet
 
Standard models
Item
Options
1AA
2B
3C
4DA
Phase
1, 3
 
 
 
 
Standard
IEC, ANSI, panel
IEC
IEC
IEC
IEC
Current, nominal
 
10
20
20
5
Current, max
 
50
80
100
6
Voltage
57-240
220
220
220
57-240
Voltage tolerance
up to 50%
+/-20%
+/-20%
+/-30%
+/-30%
Frequency
50, 60Hz
50
50
50
50
Frequency tolerance
5%
5%
5%
5%
5%
Accuracy class, active
0.2, 0.5, 1, 2
1
1
1
0.5
Accuracy class, reactive
0.5, 1, 2
 
 
 
1
Operation temperature
-10 +55C, -25 +60C, -40 +80C
-25 +60C
-25 +60C
-25 +60C
-25 +60C
LCD viewable temperature
-5 +45C, -20 +60C, -25 +80C
-20 +60C
-20 +60C
-20 +60C
-20 +60C
Case
IEC, S-base
IEC
IEC
IEC
IEC
Case material
ABS, PC
ABS
ABS
ABS
ABS
Data terminals
2 - 8
0
2
2
6
Terminal cover
short, standard
standard
standard
standard
standard
Split unit
 
 
 
 
 
LCD
1-, 2-, 3-line
1
1
1
1
No. of seals, main cover
1, 2
2
2
2
2
No. of seals, terminal cover
1, 2
1
1
1
1
No. of buttons
0-2
0
1
1
2
Sealable buttons
0-1
0
0
0
1
External battery compartment
 
 
 
 
 
Batteries
0 - 2 (RTC + power-out backup)
0
1
1
2
Battery shelf life
2 - 15 years
 
5
5
5
Power-out backup battery
5 minutes per month, 24 hours on
 
 
 
x
Control battery' condition
for none, 1 or 2 batteries
 
1
1
2
disconnection relay
none, 40-100A
 
 
60A
 
external control relay
0 - 2
 
 
 
2
Optical port
 
x
x
x
x
Card reader
 
 
 
x
 
Communication
RS232, RS485, fibre optic
 
RS485
RS485
RS485
Pulse output
active, reactive
 
 
 
active, reactive
Auxiliary pulse input
0 - 2 (water, gas meters)
 
 
 
 
modem
 
 
 
 
 
PLC
none, one-way, two-way
 
 
 
 
Tariffs
0 - 5
 
4
4
4
Seasons annually
1 - 12
 
4
4
4
Weekend days
0 - 2
 
2
2
2
Holidays annually
0 - 365
 
Unlimited
Unlimited
Unlimited
Tariff zones per day
6 - 96
 
24
24
24
Slab (step) tariffs
0 - 8
 
4
4
4
Calendar
Gregorian, with lunar holidays, local
 
 
 
 
Daylight savings time
when do you switch on/off DST
 
 
 
 
kWh
 
x
x
x
x
kVArh
 
 
 
 
x
kW
 
 
 
 
x
kVAr
 
 
 
 
x
KVA
 
 
 
 
x
Export of energy
 
 
 
 
 
max demand active
 
x
x
x
x
max demand reactive
 
 
 
 
x
Power factor
 
 
 
 
x
temperature
 
 
 
 
x
voltage
 
 
 
 
x
frequency
 
 
 
 
x
load profile active
2880, 65000
 
 
 
2880
load profile reactive
2880, 65000
 
 
 
2880
Under/ over voltage (UOV)
 
 
 
 
x
Overload (OL)
 
 
 
 
x
Overheating (OH)
 
 
 
 
x
Thresholds for recording UOV, OL, OH
programmable
 
 
 
x
Minimum duration of UOV,OL,OH to record it
programmable
 
 
 
x
CT/PT ratio
 
 
 
 
x
Allow to reset
no/yes/password+time stamp
 
 
password+time stamp
event log
300 - 3000
 
 
 
300
months billing data kept
1 - 12
 
12
12
12
record reprogramming and values' reset
 
 
 
x
x
record all communication with the meter
 
 
 
 
x
phase reversal
detect/ no
x
x
x
x
swap of phases
detect/ no
 
 
 
 
earthing load
detect/ no
 
 
 
 
phase-neutral swap
detect/ no
 
 
 
 
earth leakage
detect/ no
 
 
 
 
CT short
detect/ no
 
 
 
 
CT bypass
detect/ no
 
 
 
 
neutral off
detect/ no
 
 
 
 
magnetic influence
detect/ no
 
 
 
 
Meter open sensor
none, main cover, terminal cover
 
 
 
 
Disconnection of the meter
detect/ no
 
 
 
x
Temperature sensor
 
 
 
 
 
Shock sensor
 
 
 
 
 
Warranty
1-16 years
2
2
2
4
Operation specifics, not listed above
describe
 
 
 
 